Automatic armature slot wedge inserter
Basic Info
Model No.: ND-LSI-1W
Product Description
This automatic armature wedge inserting machine is used to insert the wedge into armature slot, so as to insulate the armature. Machine can be customized as per customer's different requirement.
Technical Parameter of wedge inserting machine
Outside Dimension | 910*880*1300(L*W*H)mm |
Equipment Weight | 250 Kg |
Motor Power | 0.75 Kw |
Work Voltage | 380 VAC |
Work Air Pressure | 0.4-0.6 hMp |
Manufacturing Product | Motor Rotor Insulated Paper |
Rotor O.D. Range | φ20-φ55 |
Length of Insulation Paper | 15-60 mm Adjustable |
(MAX) Width of wedge | 25 mm |
Rotor Slot number | 8-24 slots |
Work procedure | Feeding-install fixture-plug in discharge |
Fixture | Pneumatic Mechanical Fixture |
Feeding form | Automatic |
Lubricant form | Grease lubrication |
Rotor made by this machine
Malfunctions and Troubleshooting
Malfunction | Check |
A.Equipment not run even press start button
| n Power and air supply |
n Make sure all input signal from sensor are correct, travel switch (X10) is pressed, no signal from counter sensor (X2), push bar protector (X7) and no paper sensor(x6) and full feeding (X4). Also, there is signal from the mechanic hand (X0) and magnetic sensor (X1) of small cylinder. | |
n Brake is power off or not | |
n The feeding sensor(X3) should have signal if there is rotor on the guide way. | |
n Check cylinder and air pipe, make sure the pressure is between 0.4 and 0.6MPa | |
B. Fail to feed paper | n Check whether the paper is jammed in the feeding or discharging part, whether the upper press wheel is down pressed |
C. No action or improper action in big cylinder | n Make sure the air pressure is 0.4 -0.6MPa |
n Check whether the magnetic valve is functional. | |
n Adjust the release valve of feeding cylinder to 0.3 Mpa | |
D. Incorrect work indexing | n Adjust indexing screw |
E. No action in small cylinder | n Check whether the mechanical valve is down pressed. |
F. The position is not correct after reset | n Adjust the counter sensor screw and make sure it is on the right position after reset. |
G. Paper jam
| n If it was blocked in the forming tooling, the equipment would stop because of the protective switch on duty. If it was blocked behind the upper press wheel, press the stop button, now the mechanical hand still hold the rotors, press the single/automatic button to adjust it to manual, the mechanical hand will release the rotor, then take out the paper, and reset, adjust the button to automatic, and start the equipment. |
Notice before Operation
(1) Confirm the shipping base on packing list after unpacking and check whether the spare parts being damaged during transportation or not. It only can be used after being installed and well debugged by our technician.
(2) To make it run normally and ensure service life, the input voltage should be AC 380V (tolerance +/-10%), and the air pressure should be between 0.4 and 0.6Mp.
(3) Reliable grounding protection is required.
(4) Don`t open the door or the safety guard when the machine is running or partially stop, either put your hand or other body part into the machine
(5) Notice the running of the machine, stop it immediately when find any abnormal conditions. Only the malfunction is solved can the machine be run again.
(6) The switch should be set on single action status when you check or maintain the equipment, and the power should be turned off.
Product Categories : Armature Manufacturing Machine > Wedge Inserting Machine